Performance characteristics
■ Up to 96 analog channels
■ Maximum 1ms sampling speed per channel
■ 1kHz bandwidth
■ 1TB built-in solid state drive
■ Built-in battery
■ Universal input: voltage, thermocouple, PT100-1000, current (optional adapter required), resistance
■ Voltage: 0.01mV~100V (directly input ±100V)
■ Temperature: Thermocouple (all types), Pt100/Pt1000 (3-wire or 4-wire)
■ 5 kinds of alarms (output)
■ 4 logic function inputs with counter and frequency counter functions
■ 16-bit resolution
■ 10TFT panoramic touch screen
■ Abundant communication interfaces: USB, Ethernet, serial port WiFi
■ Lithium battery: 8h standby
■ JK Lab software (license-free)
Multi-channel handheld data logger focused on process applications
The new generation JK360 recorder is designed to test the parameters you need to record in the process: voltage test sensor test (0-100V), temperature test (thermocouple, Pt100-Pt1000), current test (optional shunt), resistance Test, count, frequency. You can visually observe the test results (graphics and numerical values) and store the test results in the recorder's internal solid-state 1TB hard drive or USB, and you can use the license-free JK Lab software for data transfer and processing on the computer.
Simple to use
The new user interface and large touch screen make this portable JK360 data logger easy to use in many data logging software, and can transfer data easily.
Multiple applications
The JK360 is a very versatile recorder in the field of process testing:
- Multi-channel temperature monitoring and recording
- 0-100V sensor monitoring and logging
- Voltage test
- Pulse count
User-friendly interface
With 10" touch screen: The user interface is very interactive. Icons and symbols make browsing very easy and time-saving.
Function | JK360-24 | JK360-48 | JK360-72 | JK360-96 |
analog channel | 24CH(two-wire) 12CH(Three-wire/Four-wire) | 48CH ( two-wire ) 24CH (Three-wire/ Four wire) | 72CH(Two-wire) 36CH(Three-wire/Four wire) | 96CH(Two-wire) 48CH(Three-wire/Four wire) |
Logical Channels (12 Channels) | Optional | Optional | Optional | / |
Output function (12 channels) | Optional | Optional | Optional | / |
Power Analysis of Single-Phase Motors and 3-Phase Systems | Optional | Optional | Optional | / |
JK360 Analog Input Specifications | ||||
Item | Content | |||
Input mode | Photorelay scanning mode, all-channel isolated input, balanced input | |||
Mode input terminal shape | Plug-in terminals | |||
Measuring parameter | Temperature, humidity, pressure, flow, gravity, heat flow, wind, etc. | |||
Measuring Range | Voltage | 0.01mv ~100.00V F.S.最高分辨率1µV | ||
Thermal resistance | type:PT100 PT1000 | |||
Thermocouple | type:K、J、E、T、R、S、B、N、 | |||
Current | 0.001mA - 20mA 最高分辨率1µA | |||
Resistance | 0.0001Ω~99.99MΩ | |||
Logic function input | Number of channels: 12 maximum allowable voltage: 24V Cat I Sampling Rate: Max. 1ms Pulse Count/Frequency Test: 0-500k | |||
digital filter | Off、2、5、10、20、40 (smooth filter) | |||
Sampling rate | 1ms -1h 1ms to 20mn V >50mV 2ms to 20mn V ≤50mV, thermocouple & Pt100-Pt1000 | |||
A/D converter | Method: ΔΣ method, 24 Bit (effective resolution: about ±1/40000 in the range ) | |||
Measurement accuracy | Voltage | ±0.1% of F.S.(full range) | ||
Temperature (thermocouple) | Types | Measuring temperature range (TS: Measuring temperature) | Measurement accuracy | |
R | 0≤TS≤100℃ | ±5.2℃ | ||
100<TS≤300℃ | ±3.0℃ | |||
300<TS≤1600℃ | ±(0.05% of rdg.+2.0℃) | |||
S | 0≤TS≤100℃ | ±5.2℃ | ||
100<TS≤300℃ | ±3.0℃ | |||
300<TS≤1760℃ | ±(0.05% of rdg.+2.0℃) | |||
B | 400≤TS≤600℃ | ±3.5℃ | ||
600<TS≤1820℃ | ±(0.05% of rdg.+2.0℃) | |||
K | -200<TS≤0℃ | ±(0.05% of rdg.+2.0℃) | ||
0℃<TS≤1370℃ | ±0.5% of rdg.+1.0℃) | |||
E
| -200≤TS≤-100℃ | ±0.05% of rdg.+2.0℃) | ||
-100<TS≤800℃ | ±(0.05% of rdg.+1.0℃) | |||
T | -200≤TS≤-100℃ | ±(0.5% of rdg.+1.5℃) | ||
-100<TS≤400℃ | ±(0.1% of rdg.+0.5℃) | |||
J | -200≤TS≤-100℃ | ±2.7℃ | ||
-100<TS≤100℃ | ±1.7℃ | |||
100<TS≤1100℃ | ±(0.05% of rdg.+1.0℃) | |||
N
| -200≤TS<0℃ | ±(0.1%of rdg.+2.0℃) | ||
0≤TS≤1300℃ | ±(0.1% of rdg.+1.0℃) | |||
Standard Contact Compensation Accuracy | ±0.5℃ | |||
PT100 | -100<TS≤100℃ | ±0.2℃ | ||
PT1000 | -100<TS≤100℃ | ±0.15℃ | ||
Current | 0.001mA- 20.0mA | ±0.1% | ||
Max. Input Voltage | Between input terminals +/- | -100V ~ 100V: p-p | ||
Between channel (1-1/(-1) | 60Vp-p | |||
Between input terminal/GND | 60 Vp-p | |||
Max. voltage (withstand voltage) | Between channel | 350Vp-p( within 1 minute) | ||
Between input terminal/GND | 350Vp-p( within 1 minute) | |||
Alarm output | Quantity | 12 alarms(A,B,C,D) | ||
output level | 0-12V | |||
Trigger | 5 | Rising edge, falling edge, rising or falling edge, high level, low level | ||
internal storage | 1TB Built-in solid state drive | |||
USB interface | 4 | |||
Ethernet | Twisted pair of RJ45 | |||
Wifi: | Built-in Wifi module can be connected to JINKO cloud platform | |||
Display | 10 inch TFT LCD touch screen, backlight, 1024*600 | |||
Power supply | 10V/4A max, with main adapter (100/240VAC) | |||
Battery | Factory option, non-removable, lithium battery | |||
battery standby | 15 hours in standby mode, 10 hours in non-standby mode | |||
Operating temperature | 0 °C -40°C,80% RH(no condensation) | |||
storage temperature | -20°C - 60°C | |||
Size | 210*295*105mm | |||
Weight | 2.5kg | |||
Safety | CAT I 100V, in accordance with IEC61010-1 | |||
Accessories | 100/240V main adapter, manual (CDROM), 1 piece of 25-pin male connector, stylus, rag, screwdriver | |||
Warranty | 2 years | |||
■ Nuclear and thermal power plant application description:
• Check the output of sensors, switches and other signals in the power plant.
• Acquire the signal for a long time to discover the cause of the input failure. Securely record data on both print and 1TB hard drives
• Inputs: 4 analog channels and 2 PT100 temperature sensors
• Main advantages: easy to use, fast, built-in storage.
■ Aero-engine test application description:
Goal: They need to get pressure, speed and temperature. These parameters must be measured at different locations in the engine.
Inputs: • Channel 1 - Test pressure with pressure sensor
• Channel 2 - Test RPM with Proximity Sensor
• Channel 3 - Thermocouple test temperature
• Channel 4 - voltage or current depending on test conditions
Main advantage: Easy to use (friendly interface), handheld and battery-operated; easy to carry to the field.
■ Aviation - landing hydraulic device test
Application description: The hydraulic performance test of the landing gear of the R&D department. The test is carried out on the prototype and also under simulated conditions.
Goal: Get the voltage from the controls to the landing gear, the pressure on the hydraulics, the displacement and rotational speed of the wheel landing.
Inputs:
• Channel 1 - Voltage from the control section.
• Channel 2 - pressure level in bar - measured with a suitable pressure transducer.
• Channel 3 - Movement or displacement of the landing gear.
• Channel 4 - Speed or Temperature.
Main advantages: easy to use (friendly interface), handheld and with battery; easy to carry to the field for use (compared to oscilloscope) calculation of Forces and Loads in x-y mode.
■ Unmanned Aerial Vehicle Testing, Missile, Missile Subsystem Testing
Application Description: Organizations that manufacture drones and missiles for defense want to test various parameters such as vibration, shock, pressure, temperature, voltage, etc. from different sensors/accelerometers/pressure sensors/thermocouples, etc. Users need to test the behavior of their R&D department subsystems. Tests were carried out on prototypes and also under simulated conditions.
Goal: Collect various parameters, such as pressure, vibration, rotational speed, temperature, voltage, etc. These parameters must be measured at different locations in the subsystem.
Inputs: Many types of sensors/actuators etc are used for recorders to send signals/inputs.
Main advantage:
• Easy to use (friendly interface), online printing.
• The 360 recorder has 1 mV full scale sensitivity and 25 M ohm input impedance and does not require any additional signal amplifier to amplify the sensor signal.
■ Helicopter. Rotor engine test. Rotor research and design
Application Description: Users need to test the performance of rotor motors in their R&D department. Tests were carried out on prototypes and also under simulated conditions.
Goal: Collect various parameters, such as pressure, vibration, rotational speed, temperature, voltage, etc. These parameters must be measured at different positions on the rotor.
Inputs: Many types of sensors/actuators etc for sending signals/inputs to the recorder
Main advantage:
• Easy to use (friendly interface), online printing.
• The JK360 recorder has 1 mV full-scale sensitivity and 25 M ohm input impedance, which does not require any additional signal amplifier to amplify the input signal output by the sensor/actuator, which is in line with user needs.
• Also, the chart speed is 200mm/sec - very fast.
■ Validation of automotive sensors in automotive equipment factoriesApplication Description: Sensor testing and analysis of automotive sensor transmit and PWM buses.
Goal: Control and record sensor bus information.
Inputs:
• 36 analog channels, 0-10 A.
• 12 transmit channels
• 20 PWM channels
Main advantage:
• Ease of use with specific software.
• Re-enable function on trigger.
■ Monitor car sensors
Application description: Data acquisition system for long-term test temperature and partial output of gasoline engine control unit.
Goal: Display data acquisition in real time (digital mode).
Inputs: 12 general purpose channels and 12 multiplexed channels.
Main advantages: Ease of use, large number of display and memory channels.
■ Monitor voltage and current
Application description: A data acquisition system for monitoring low voltage and high current in the busbar for industrial low-voltage switchgear test.
Goal: Acquisition of voltage, current and some temperature. Using the JK360 it is possible to combine temperature measurement with power analysis recording.
Inputs: 6 general purpose channels and 12 multiplexers
Main advantage: Ease of use, speed memory and power analysis
■ Industrial Controls and Drives
Application Description: During the vibration test, the JK360 monitors the opening or closing of 3 relays simultaneously and records the vibration frequency.
Goal: Acquisition of voltage high and low level (0–10V) and frequency (1KHz). Data acquisition loggers allow very long storage with various triggers combined with various measures.
Inputs: 12 general purpose channels