Performance characteristics:
● Simultaneous measurement of multiple test units (up to 8 units);
● Universal input: current, voltage, thermal resistance, thermocouple, pressure;
● The seamless display of historical data trends;
● Screen information is stored on U disk;
● Automatic upgrade instrument operation software through USB HOST;
● Chinese and English optional operation interface;
● RS232, USB HOST, USB, Device and LAN can facilitate data communication with PC and remote control of instruments;
● Free plug in each test unit;
● Temperature compensation function (TC);
● The WiFi interface is used to implement online operations;
● Data storage function to facilitate real-time preservation of measurement results;
● Flexible and convenient file operating system;
Display Characteristics:
● Adopt high brightness color 10.1 inch TFT LCD screen, CCFL backlight and clear picture;
● Rich display, powerful data search function, status indicator function;
● Intuitive touch screen operations;
● With flashing alarm display, at the same time indicate the lower and lower limit, upper limit and upper limit alarm of all channels;
● There are four basic pictures: digital display, bar picture display, real-time curve picture, recall curve and picture;
● Real time curve recording interval of 1 second ~9999 seconds, step setting, corresponding to the whole screen curve time 30 seconds ~300 minutes;
● Recalling curve intervals are set from 1 second to 9999 seconds;
● Recalling the curve reading cursor function.
Flexible construction
● When more channels are needed, the i/o module can be added;
● Relay alarm output.
Basic function
● The use of ARM microprocessor can achieve up to 64 signals acquisition,recording, display and alarm at the same time;
● The display accuracy is high, and the basic error is ±0.2% F·S;
● Built in GB2312 Chinese characters library, using full spelling input method;
● Equipped with standard three USB interfaces, the U disk is used to transfer historical data quickly and conveniently; and it can also access keyboard and mouse;
Power supply
● With high-quality brand-name switching power supply, it can work normally in AC voltage AC 85V~265V wide voltage range;
● Provide transmitter DC 24V isolation distribution;
● Through EMCIII level, ensure the instrument work well in bad environment.
Input signal
● DC current, DC voltage, thermal resistance, thermocouple, pressure type, input through key input, isolation universal input;
● Temperature and pressure compensation supports signal input, constant selection, and provides a variety of compensation models, such as superheated steam, saturated steam, pressure compensation, and other compensation models;
● DC current: (4~20) mA, (0~10) mA, (0.01~20.00) mA;
● DC voltage: 0.01mV-100V;
● Thermal resistance: Pt100 (three wire system);
● Thermocouples: K, S, R, B, N, E, J, T;
● Temperature & humidity: 2305 temperature and humidity probes can be tested directly (-20℃ to 110℃) (humidity 20% to 98%);
●Optional AM2001 humidity module (3%, condition: 25℃, 60%RH, other conditions are accuracy 5%);
● Other input signals or indexing numbers should be specified when ordering.
Communication and print interface (optional function)
● photoelectric isolation;
● RS232 and RS485 standards;
● Communication rate 960019200, 57600, 115200 by setting selection;
● Supporting test software, providing configuration software and application software technical support;
● Optional ModBus RTU protocol and communicate with host computer;
● Support standard ModBus RTU protocol (optional function), not only supporting our company's data management software, but also support popular configuration software such as MCGS and King view.
Output:
● Relay alarm output; configuration 12 alarm function;
● Configurable 8 point Transmission output, photoelectric isolation, error is less than ±0.2% F·S;
● Current output (4~20) mA, (0~10) mA, (0~20) mA are optional;
● Voltage output (0~5) V, (1~5) V optional;
● The factory defaults setting is (4~20) mA,and other types of specified demands should be marked when ordering.
Storage:
Large capacity internal memory 4G.
It supports long time and multi-channel recording of large capacity FLASH, and can quickly transfer data from the FLASH to the computer through the U disk. The capacity of the built-in FLASH is 64M bytes, if the 8 channels is recorded once in 20 seconds. It can record 65 days and record the data of all channels as fast as 100ms.
JK9000 Analog input specification | ||||
Item | Content | |||
Input type | Photoelectric relay scanning mode, full channel insulation input, balanced input | |||
Mode input terminal shape | M3 Screw terminal | |||
Measuring range | Voltage | 0.01mV-100V F.S.(full range),Highest resolution 1µV | ||
Thermal resistance | Type:PT100 | |||
Thermocouple | Type:K、J、E、T、R、S、B、N | |||
Humidity | Digital signal input (Switzerland Rotronic accuracy 0.8%) (domestic high accuracy 1.5%) | |||
Current | 0.01mA-20.00mA | |||
Sampling rate | 100ms (full channel) | |||
Measuring accuracy | Temperature/ thermocouple | Types | Measuring temperature range (TS:measuring temperature) | Measuring accuracy |
R | 0≤TS≤100℃ | ±5.2℃ | ||
100<TS≤300℃ | ±3.0℃ | |||
300<TS≤1600℃ | ±(0.05% of rdg.+2.0℃) | |||
S | 0≤TS≤100℃ | ±5.2℃ | ||
100<TS≤300℃ | ±3.0℃ | |||
300<TS≤1760℃ | ±(0.05% of rdg.+2.0℃) | |||
B | 400≤TS≤600℃ | ±3.5℃ | ||
600<TS≤1820℃ | ±(0.05% of rdg.+2.0℃) | |||
K | -200<TS≤0℃ | ±(0.05% of rdg.+2.0℃) | ||
0℃<TS≤1370℃ | ±(0.5% of rdg.+1.0℃) | |||
E | -200≤TS≤-100℃ | ±( 0.05% of rdg.+2.0℃) | ||
-100<TS≤800℃ | ±(0.05% of rdg.+1.0℃) | |||
T | -200≤TS≤-100℃ | ±(0.5% of rdg.+1.5℃) | ||
-100<TS≤400℃ | ±(0.1% of rdg.+0.5℃) | |||
J | -200≤TS≤-100℃ | ±2.7℃ | ||
-100<TS≤100℃ | ±1.7℃ | |||
100<TS≤1100℃ | ±(0.05% of rdg.+1.0℃) | |||
N | -200≤TS<0℃ | ±(0.1%of rdg.+2.0℃) | ||
0≤TS≤1300℃ | ±(0.1% of rdg.+1.0℃) | |||
Standard contact compensation accuracy | ±0.5℃ | |||
PT100 | -100<TS≤100℃ | ±0.2(must be customized) | ||
A/D converter | Mode:ΔΣ,16Bit(Effective resolution:±1/40000) | |||
Maximum input voltage | Between input terminal +/- | -100V~100V: p-p | ||
Between channel(1-1/(-1) | 60Vp-p | |||
Between input terminal/GND | 60Vp-p | |||
Maximum withstand voltage | Between channels | 350Vp-p(within 1 minute) | ||
Between input terminal/GND | 350Vp-p(within 1 minute) | |||