Service hotline
0086-519-85563477

JK9306 series electrical parameter test ceremony The latest generation of intelligent multi-channel power test products developed by our company adopt the latest measurement principles, super anti-interference ability to ensure the accuracy and consistency of the test, 4.3-inch high-definition TFT color screen display parameters are comprehensive and simple , Rich in functions, highly humanized. Products are widely used in many fields such as household appliances energy consumption test, lighting appliances / LED lamps power consumption test, motor and motor test, charger and switching power supply test.
Features:
■ High-definition 4.3-inch TFT color display, displaying all channel data at the same time
■ Single-channel dual-channel or four-channel simultaneous testing, greatly improving production efficiency
■ The minimum test current is 0.05 mA, and the power is 0.001W, which is suitable for small power tests such as standby power consumption.
■ All measurements are true effective value Trms
■ Automatic range, accuracy: 0.5 level
■ Simple and quick setting upper and lower limit alarm function, support data lock
■ Super anti-interference ability
■ Standard RS232C and USB Device communication interface software
Main technicial parameters:
| Model | JK9306 | JK9306B | JK9306D | JK9305 | JK9305B | JK9305D |
| Wiring | single-phase | |||||
| Input channel | single channel | double channel | 4 channel | single channel | double channel | 4 channel |
| Display | 4.3 inch TFT color screen | |||||
| test parament | Voltage V、Current A、Active power W、Power factor PF、Frenquancy Hz Electric energy accumulation | |||||
| Measurement way | Trms | |||||
| Voltage range | 5-600V AC (range automatic switching), peak voltage: 700V AC, 1.2 times overload for a long time Minimum test voltage 5V AC resolution 0.01V | |||||
| Voltage Input | AC | AC | ||||
| Current range | 0.2mA - 200mA 0.2A - 20A automatic switching: Up cut 200mA / down cut 150mA | 0.15mA - 5A AC(range automatic switching) Mininum test current0.15mA | ||||
| Resolution | Voltage 0.01V Current:0.01mA(0.2mA-200mA) 0.01A ( 0.2A-20A) Power: 0.01W Power Factor:0.001 | Voltage:0.01V Current:0.01mA (0.2mA-200mA) 0.01A ( 0.2A-5A) Power: 0.001W Power factor:0.001 | ||||
| Current input | AC | |||||
| Power Range | 0.01W-3000W 0.1W-12kW | 0.001W-3000W | ||||
| Power factor range | 0.001-1.000 Calculation method: Watt (W) ÷ [Voltage (V) × Current (A)] = Power Factor (PF) PF> 0.5 ± (0.1% reading + 0.1% range) PF <= 0.5 ± (0.2% reading + 0.2% range) | |||||
| Frequancy range | 45-65Hz | |||||
| Measurement accuracy | Voltage: ± (0.3% reading + 0.05% range) Current: ± (0.4% reading + 0.05% range) | |||||
| Measurement speed | 5 times/second | |||||
| Input impedance | ≥1MΩ(all voltage ranges) | |||||
| Communication interface | RS-232C,USB Device | |||||
| Data storage | USB HOST | |||||
| Limit alarm | YES | |||||
| Input voltage range | 110V/220V AC, 50/60 Hz | |||||
| Size and Weight | Instrument size:355mm*225mm*112mm,length*width*height Hole size:225mm*99mm,width*height,weight about 1.7Kg | |||||